Sobetracom

Import guide · Ghana

Importing medical equipment into Ghana: FDA registration and permits

In Ghana, medical devices come under the Food and Drugs Authority (FDA), whose mandate rests on the Public Health Act, 2012 (Act 851). The principle is simple and strict: only registered products may be imported, by a licensed company, under an import permit obtained before shipment. Donations get limited flexibility under a guideline of their own.

This guide is for ministries, hospitals, NGOs and donors buying diagnostic equipment, medical furniture or consumables in Europe for Ghana. It summarises the guidelines published by the FDA and flags what must be settled before an order is placed.

Updated on 21 October 2026

Registration comes first

The FDA grants market authorisation for Class I to IV devices on applications made by the manufacturer or a local agent. Separate forms apply to Class I and to Classes II to IV, reflecting closer review for higher-risk devices. The importer, for its part, needs a licence as an importer of medical devices, assessed against Good Distribution Practice.

For a buyer, the first check is the status of the chosen model: is it already registered in Ghana, and by whom? If so, the purchase goes through a licensed importer. If not, registration by the manufacturer or its local agent has to come before import, which affects the timetable.

Import permits and their conditions

The import guideline issued on 1 March 2016 restricts importation to companies registered with the Registrar-General's Department and licensed by the FDA. The permit is granted before import, presented to customs only once and valid for 1 calendar year. Vetting, together with the proforma invoices, can take up to 24 hours. The permit shows the product registration number, manufacturer, country of origin, batch number and CIF value, among other details.

Shelf life can rule a consignment out: at least 60% must remain on arrival, rising to 80% for products with a total shelf life under 24 months. The FDA's Imports and Exports Control page adds that permits are now handled on ICUMS and that clearing agents can apply without waiting for the goods to arrive.

Donations: a first delivery without registration

The donation guideline issued on 1 December 2017 allows a device not registered in Ghana to be donated once without registration, provided the recipient or donor notifies the FDA before it arrives. A second donation of the same device is only allowed once it has been registered. A non-resident applicant must appoint a local agent, who may be the receiving institution.

The technical requirements are specific. Used equipment needs its maintenance history, user and installation manuals, a decommissioning report and an engineer's report on its condition. Refurbished equipment needs a GMP certificate, the refurbisher's licence and a Certificate of Free Sale. Single-use devices may be donated only if never used and with at least 6 months' shelf life left on arrival.

Entry points and inspection

Products are inspected by the FDA at the point of entry before release to the importer. The guideline names Tema Harbour, Takoradi Harbour and Kotoka International Airport as approved ports. The FDA's Centre for Import and Export Control covers 11 entry points in all, but medical devices should be routed through an approved one.

Sobetracom is neither a licensed importer nor a local agent in Ghana. From Belgium, we check with manufacturers the registration status of each model, the shelf life of the batches and the documents needed for a donation or refurbished equipment, then pass the file to the importer or recipient. FDA requirements should be reconfirmed with them before shipment, particularly for a first donation.

Frequently asked questions

Can an NGO donate a medical device that is not registered in Ghana?
For a first donation, yes, under the FDA guideline, provided the Authority is notified before arrival. A second donation of the same device requires it to have been registered in the meantime.
How much shelf life must consumables have on arrival?
At least 60% of their shelf life, or at least 80% where the total shelf life is under 24 months. Donated single-use devices must have at least 6 months left.
Does the FDA import permit clear the goods through customs?
No. The FDA states that it issues import permits, not clearing permits. The permit, handled on ICUMS, sits alongside the customs formalities.

Sources

  1. Food and Drugs Authority Ghana, site officiel (October 2026)
  2. Food and Drugs Authority Ghana, Medical Devices Registration (October 2026)
  3. Food and Drugs Authority Ghana, Guideline for Importation of Medical Devices (October 2026)
  4. Food and Drugs Authority Ghana, Guideline for Donation of Medical Devices (October 2026)
  5. Food and Drugs Authority Ghana, Imports and Exports Control (October 2026)

This page summarises public sources as of the date shown. It does not replace the official text: check it before committing to a purchase, a bid or a shipment.

A project in Africa? Let's talk.

Tell us what you need and where it goes. We come back to you with first leads.