Equipment sourcing · IT and broadcast
Buying optical fibre for a network in Africa: fibre types, cables and protection
Linking campus buildings, connecting a transmitter to its control room, rolling out a government network across a city: optical fibre has become the backbone of IT and broadcast projects. In Africa, the cable also has to cope with heat, floods, roadworks and a threat that sales sheets rarely mention, termites and rodents.
This guide helps write the cables and accessories part of a tender: which fibre type to ask for, which performance to require, how to protect the cable according to how it is laid, and what to order with it so that it can be installed and repaired.
Updated on 21 October 2026
G.652.D for transport, G.657 for access
The reference single-mode fibre is described in ITU-T Recommendation G.652, revised in 08/2024: its zero-dispersion wavelength is around 1310 nm and it is also used around 1550 nm. The G.652.D sub-category is the usual choice for transport links and urban backbones.
For access networks, risers and cramped equipment rooms, ITU-T G.657 describes fibres that are less sensitive to bending. Category A fibres remain compliant with G.652.D, so they can be spliced into the same network. The difference shows in the minimum bend radius: 10 mm for G.657.A1, 7.5 mm for G.657.A2 and 5 mm for G.657.B3. Choosing A1 or A2 for building drops makes installation easier without creating incompatibility.
Performance figures for the lot
For G.652.D cable, the Recommendation sets a maximum attenuation coefficient of 0.40 dB/km from 1310 nm to 1625 nm and 0.30 dB/km across 1530-1565 nm. Those values do not apply to patch cords and indoor cables, for which IEC 60794-2-11, cited by the ITU, allows 1.0 dB/km or less.
The specification should also state the fibre count, construction (loose or tight buffered), sheath type, installation method (aerial, duct, direct burial, indoor), length per drum and the acceptance tests expected, with OTDR measurement of every fibre. Spare fibres in the cable cost little and avoid pulling a second cable later.
Termites, rodents and choosing the protection
ITU-T Recommendation L.46, renumbered L.161 in 2016, lists biological attacks on cables: rats, mice, moles and other rodents, but also termites and ants, whose acidic secretion corrodes lead. It matches each threat with a countermeasure. Steel wire, fibreglass or aramid armouring resists rodents. A polyamide sheath protects against ants and termites. Helical steel or brass tape stops birds and termites, and galvanised iron guards go where the cable emerges from the ground.
For buried or ducted cable in tropical areas, explicitly requiring termite and rodent protection, and stating its type, prevents a cheaper unarmoured offer being treated as equivalent.
Accessories, tools and maintenance
A cable is useless without splice closures, patch panels, splice trays, connectors, patch cords and splice protectors. Tools matter just as much: fusion splicer, cleaver, OTDR, cleaning kit. The budget should cover training technicians in splicing and testing, plus a repair kit for accidental cuts. Drums are heavy and bulky, and asking for their dimensions and weight in the bid helps plan container loading and handling on arrival.
Frequently asked questions
- Is multimode fibre needed to link a TV control room to its equipment?
- Inside a building, multimode fibre is still used over short distances. Between buildings or distant sites, single-mode G.652.D or G.657 is the rule. The choice should follow the optical modules of the equipment being connected.
- How does Sobetracom compare fibre cable bids?
- We check the declared fibre category, guaranteed attenuation, cable construction and protection, length per drum, test certificates and manufacturing lead time, then compare on a like-for-like basis. In Guinea, our relays followed a supply of IT and broadcast equipment for television. The client's licensed customs broker then confirms the tariff classification of cable and accessories.
Sources
- UIT, Recommandation ITU-T G.652 (08/2024) (August 2024)
- UIT, Recommandation ITU-T G.657 (08/2024) (August 2024)
- UIT, Recommandation ITU-T L.46 (October 2000)
- UIT, page de la Recommandation ITU-T L.46 (October 2026)
- Sobetracom, références clients (September 2026)
This page summarises public sources as of the date shown. It does not replace the official text: check it before committing to a purchase, a bid or a shipment.