Electrical test equipment and gas detectors for projects in Africa
Multimeters, clamp meters, insulation testers, earth testers, power analysers and gas detectors are small and inexpensive on the scale of a project, but they bear directly on the safety of the people using them. An underrated instrument connected to an industrial switchboard can cause a serious accident.
Sobetracom supplied electrical and gas analysis and measurement equipment for a project supported by the French Development Agency (AFD) in the DRC. This page covers what the specification should require and how to prepare for use on site.
Updated on 20 October 2026
Instrument safety: IEC 61010 and measurement categories
The base standard is IEC 61010-1:2010, covering the safety of electrical equipment for measurement, control and laboratory use. Since that edition, testing and measuring circuits fall under a particular standard, IEC 61010-2-030, now in its second edition of 2017. It added requirements against transient overvoltages for circuits measuring mains voltage, and requirements for measurements from 1 000 V to 1 500 V DC, relevant to solar installations.
In the specification, state for each instrument the measurement category and voltage required by where it will be connected: socket outlet, distribution board or origin of the installation. Leads, probes and clamps must carry at least the same category as the instrument, since IEC 61010-2-030 refers to IEC 61010-031 for probe assemblies and IEC 61010-032 for current sensors.
Testing installations: IEC 61557
To verify the safety of a low-voltage installation (continuity, insulation, earth resistance, loop impedance, RCDs), instruments should comply with the IEC 61557 series. Part 1, IEC 61557-1:2019, covers networks up to 1 000 V AC and 1 500 V DC and expresses measurement uncertainty according to ISO/IEC Guide 98-3:2008. A multifunction tester complying with the relevant part of the series for each measurement gives results that are comparable from one technician to the next.
For power quality analysis, ask about memory, recording time, battery operation and data software, with its licence.
Gas measurement: specify the gas and the atmosphere
For flammable gases, IEC 60079-29-1:2016 sets construction, test and performance requirements for portable, transportable and fixed detectors used in explosive atmospheres; it has now been revised by EN IEC 60079-29-0:2026. In Europe, such instruments also fall under Directive 2014/34/EU. State the gas or gases to detect, the measuring range, the sensor type and the area of use: a multi-gas detector for confined space entry meets a different need from a combustion analyser.
Sensors age and need calibration with reference gases. Plan for calibration cylinders, checking that they can travel by the chosen transport mode, and for spare sensors.
Calibration, climate and training
A measuring instrument is only useful if it is calibrated. Require a calibration certificate on delivery, ideally from an accredited laboratory, and plan recalibration: locally if a laboratory exists, otherwise by periodic return to Europe. Heat and humidity degrade displays, batteries and sensors, so ask for the operating temperature range and ingress protection rating, and include carrying cases.
Training matters as much as the instrument: choosing the category, measuring safely, reading results. From Belgium, Sobetracom compares offers from several manufacturers on these criteria, checks the documentation and coordinates shipping, with its relays in the DRC. Import requirements for instruments and calibration gases should be confirmed with the licensed customs broker before dispatch.
Frequently asked questions
- Which safety standard should an industrial multimeter or clamp meter meet?
- IEC 61010-1 and IEC 61010-2-030, with a measurement category suited to the most exposed connection point.
- Which standard applies to an installation tester?
- The IEC 61557 series, whose part 1 of 2019 covers low-voltage networks up to 1 000 V AC and 1 500 V DC.
- Can calibration gas cylinders ship with the detectors?
- Not always: they are goods subject to specific transport rules. The shipping mode should be checked with the freight forwarder before ordering.
Sources
- Sobetracom, références clients (September 2026)
- Genorma, fiche EN 61010-1:2010 (October 2026)
- Genorma, fiche EN IEC 61010-2-030:2021 (October 2026)
- Genorma, fiche EN IEC 61557-1:2021 (October 2026)
- Genorma, fiche EN 60079-29-1:2016 (October 2026)
This page summarises public sources as of the date shown. It does not replace the official text: check it before committing to a purchase, a bid or a shipment.