Sobetracom

Equipment sourcing · Water and infrastructure

Water treatment units for projects in Africa: choose the process before the machine

A water treatment unit, whether a skid-mounted packaged plant or an installation built on site, is only as good as the match between its treatment process and the water it receives. A river loaded with silt in the rainy season, an iron-rich borehole and a clear lake do not call for the same steps. Buying "a unit of so many m3/h" without a raw water analysis leaves the supplier guessing.

This page helps a ministry, utility or NGO write an enquiry for a treatment unit. It draws on the technical notes for emergencies published by WHO with WEDC, which describe the treatment chain and its field weaknesses, and on the WHO scheme for evaluating household water treatment technologies.

Updated on 20 October 2026

Raw water analysis comes first

The file sent to manufacturers should include raw water results over several seasons: turbidity, suspended solids, pH, iron and manganese, faecal contamination and any suspected chemical pollutant. WHO technical note No. 11 gives two limits that shape the process. Chlorination works only on water below 5 NTU turbidity, with pH ideally between 6.8 and 7.2. And chlorine does not deal with Cryptosporidium or chemical contaminants: if either is present, a suitable filtration stage or specific treatment is needed.

Turbid surface water therefore needs clarification ahead of disinfection, whereas clear borehole water may need only polishing filtration and chlorination.

Describe the process stage by stage

WHO note No. 6 describes the typical chain: intake with screening and sometimes aeration; settlement, helped by a coagulant such as alum; filtration through roughing filters, rapid gravity filters or membranes; then chlorine disinfection, which also protects the network against recontamination. Membranes give high-quality water but are complex to operate.

In the tender, describe each stage by its function and expected performance (outlet turbidity, contact time, target residual chlorine) rather than by a set technology. That way a packaged plant with lamella settlers and a membrane unit can be compared on one basis, adding for each the energy demand, chemicals required and operator skill level.

Chemicals, power and spares

The same WHO note says a modern works depends on skilled operators, chemicals, electricity and machinery that functions. It observes that chronic underfunding and a lack of skilled staff mean many plants do not work properly, emergency or not. The purchase should therefore cover what will keep the unit running after delivery.

Chemicals such as alum, lime and chlorine should be ordered early because supply can be slow; the file states expected dosing per cubic metre and the initial stock delivered with the unit. For power, WHO recommends mobile generators where the mains fail, so the unit's absorbed power and starting peaks belong in the offer. Spare parts can take time to arrive: dosing pumps, membranes or cartridges, sensors and controllers should come with a first-maintenance kit.

Small units, household treatment and testing

For a health centre or school, the choice is sometimes between a small communal unit and point-of-use treatment. WHO note No. 5 says the latter is quicker and cheaper to deploy than a centralised system but harder to manage. For those products, the WHO international scheme set up in 2014 rates technologies at 3 levels, from 1 to 3 stars, by their ability to remove bacteria, viruses and protozoa, and its results guide states and procuring UN agencies. The latest report, published on 18 March 2026, covers 21 products.

In every case, include simple test kits for turbidity, pH and chlorine with their reagents. From Belgium, Sobetracom consults manufacturers of plants and packaged units, compares the processes offered against the water analysis, checks technical references and arranges operator training with the supplier. Relays in DR Congo, Burundi, Guinea and Nigeria follow delivery and start-up; chemicals shipped with the unit must be declared to the licensed clearing agent before dispatch.

Frequently asked questions

Is chlorination alone enough for river water?
Rarely. According to WHO note No. 11, chlorination needs turbidity below 5 NTU and has no effect on Cryptosporidium. Silty river water first goes through clarification and filtration.
Should we prefer a membrane unit?
Membranes give high-quality water, but WHO considers them complex to operate. The choice depends on raw water, available power, access to spares and the skills of operators on site.

Sources

  1. OMS et WEDC, Technical Notes on Drinking-Water, Sanitation and Hygiene in Emergencies, n° 6 : Rehabilitating water treatment works after an emergency (July 2013)
  2. OMS et WEDC, Technical Notes on Drinking-Water, Sanitation and Hygiene in Emergencies, n° 11 : Measuring chlorine levels in water supplies (July 2013)
  3. Organisation mondiale de la Santé, International Scheme to Evaluate Household Water Treatment Technologies (October 2026)
  4. OMS et WEDC, Technical Notes on Drinking-Water, Sanitation and Hygiene in Emergencies, n° 5 : Emergency treatment of drinking-water at the point of use (July 2013)

This page summarises public sources as of the date shown. It does not replace the official text: check it before committing to a purchase, a bid or a shipment.

A project in Africa? Let's talk.

Tell us what you need and where it goes. We come back to you with first leads.